Views: 0 Author: Site Editor Publish Time: 2016-12-13 Origin: Site
Reason 1: open time of the production line is too long
Solution: shorten the production line’s open time or extend the open time of adhesive
Reason 2: dosage of used adhesive is not enough
Solution:increase the dosage of using adhesive
Reason 3: pressure force is weak or hold time is not enough
Solution: increase the pressure force or extend the hold time
Reason 4: gel temperature is too low
Solution: increase the gel temperature
Reason 5: base material is cold
Solution: preheating the substrate material
Reason 6: the base material has got damp
Solution: drying the base material
Reason 7: the surface of substrate material has been polluted
Solution: clean the surface of substrate material